Water

Storage Tanks
At Allied Pumps, we manufacture and install water storage tanks for a variety of applications, such as fire protection, truck wash facilities, potable water storage, and many more.
OVERVIEW
Overview Heading
Our mining and industrial water tanks are designed to meet Australian Standards and can be customised to suit your site’s specific requirements.

All our water storage tanks are built from heavy-gauge steel, making them robust and long-lasting. The galvanised tanks come in capacities ranging from 10 kL to 5 ML and are available with insulation to cater to the hottest climates.

The Allied Pumps team has the capability to install and serve the remotest of locations, with many of our liner tank jobs taking place in the Pilbara and Goldfields. Moreover, all our mining and industrial water tanks are independently Engineer Certified to ensure they meet the highest of standards.
MINING
Our Water Tanks
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua.
A durable and impact resistant above ground polyethylene or glass reinforced plastic corrugated tank for collecting and storing water. Allied
Allied Pumps’ Polyethylene Underground Retention Tanks are tough, versatile liquid storage systems that have a standard capacity range from 5,000
Allied Pumps’ GRP Panel Type Water Storage tanks are manufactured from SMC using the hot pressed metal matched mould method
Our Tank Materials & Finishes
At Allied Pumps, we only use the most durable materials for our water storage tanks. Corrosion resistance is at the focus of our work, especially when designing steel tanks for liquids like raw and salt water. Our selection of tanks materials and finishes includes:
Applications
- Fire Protection
- Dust Suppression
- Truck Wash
- Potable Water
- Raw Water
- Sewage
- Wastewater
Australian Standards
AS2304-2011
Water storage tanks for fire protection systems
AS1657-2013
Fixed platforms, walkways, stairways, and ladders
AS4100
Steel structures
AS4600
Cold form steel structure
AS1170.4
Earthquake loads
AS2118
Raw sprinkler systems
AS/NZS4020
Testing of products for use in contact with drinking water
AS2239
Galvanic (sacrificial) anodes for cathodic protection
AS1170.2
Wind loads
AS2419.1
Raw hydrant (tanks)
AS1170.1
Live and dead loads
HOW IT WORKS
Our Tank
Installation Process
Our steel water tanks are fabricated at our manufacturing facilities and delivered to the site for installation. To minimise the risk of working at height, the platforms, top access hatch, and tank roof are built after the first ring/strake of the tank is complete.


The galvanised tanks are then lifted using electric jacks to the specified height.
Step 1
Tank Jacks are fitted to every vertical joint
around the tank.
Step 2
Tanks are lifted to a suitable height to enable working inside tank.

Step 3
All external fittings and accessories fitted once tank is at specified height.
PROJECTS
Explore Other Projects
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua.
It’s been 25 years, and the Bickley Booster Pump Station is still going strong. In 1992, we took on this project. This challenge began with the need to solve a low-pressure problem in the Orange Grove area. A dual pump system operating on a variable speed control was installed. This included the base, pipework, valves, control system and pressure vessel. The pump set is still functioning correctly and addressing the original issue. This project represents the quality and endurance of our pump systems.
Allied Pumps creates insulated circular steel panel liner tank for the Karratha Health Campus to meet clients cold water requirements. We were able to meet the client’s stringent requirements to produce a cost effective, potable water tank that could withstand the extreme weather conditions. Rising to the challenge, this project was Allied Pumps first insulated circular steel panel liner tank complete with a cold water circulating program.
Royal Perth Hospital is a 450-bed teaching hospital located on the north-eastern edge of the CBD of Perth in Western Australia. The project started with a site visit by us. We measured and discussed the design needs for the fire pump set refurbishment. The first step was to disable and remove the existing system. This removal was the same day as the new system’s delivery so there was no site storage required. The new system was then installed in one day. This was a quick turnaround time, and we were able to meet the timeframe to ensure minimal downtime.
The Christmas Island International Airport serves visitors and residents of Christmas Island, a territory of Australia in the Indian Ocean. The building required a containerised system for its fire pump set. We were able to offer expert advice and help in the installation and usage of the system for the Christmas Island Airport personnel.
Formed in 1905 to obtain, treat and distribute water supplies, the Bunbury Water Board has served the people of Bunbury for over 100 years. The city’s early settlers knew of water stored naturally underground and tried to use it to replace the Collie River and the Preston River, which were the only sources of water for drinking in those days. We supplied the first variable speed system to the water authority. It’s still being used today.
Station street markets were historic markets located in Subiaco that closed in 2015 after 30 years. In 2017, the site became part of a $96M redevelopment plan. We are currently working on this project constructing custom 4.70 diameter by 9.20 high fire water tanks (holding 150 kL each). These are custom specifications to meet the site’s needs. Creating custom length panels highlights our ingenuity and abilities to accommodate clients.
A residential complex in Perth required an innovative way to pump water to reduce power consumption and improve sustainability. In many new buildings, there is a push to use a single basement tank with basement pumps pressuring all the way to the top of the apartment block. However, Allied Pumps had a better solution. A small pump and tank at the basement of the apartment block transfers water to the rooftop tanks at a low flow, keeping the rooftop tank full. A smaller, variable speed pump supplies the top few floors, whilst the levels below are fed by gravity. With a roof top tank full of water at all times, even during a power outage, the system can still supply the residents with water. Smaller pumps, simpler control logic, and reduced tank capacities all kept initial costs low and provided huge benefits for the complex.
Blockages occur fairly regularly at Graylands Hospital, Western Australia’s largest mental health facility. Objects and clothing were often being introduced into the plumbing system. With 1,053 fixtures, the system needed help breaking up these foreign objects. Two of their grinder pumps were not properly handling foreign objects. After much investigation, the most practical option was to install a channel grinder in the existing mechanical screening pit. We designed specialised guiderails from 316 stainless steel. They were built in-house to suit the existing concrete structure. This solved the issue and eliminated peak flow blockages. The system has now been up and running for 24 months with no issues.
The proposed fibreglass storage tank had an extended lead time of 14 weeks. To ensure schedules were kept, we recommended a galvanised tank, which was a first for us. This was an experience of trial and learning. Everything went smoothly providing the client with a viable solution within the requested timeframe.
The National Anzac Centre is one of Australia’s most important cultural pilgrimages. Located within Albany’s heritage listed Princess Royal Fortress, the centre overlooks the actual harbour from which over 41,000 men and woman departed Australia for the Great War. The project required a complete sewage system in a short amount of time. The system needed to handle minimal sewage flow but be prepared for high peak loadings. This is often hard to deliver, but our systems delivered a solution to ensure optimal operation.






















































![[Pyrokos] Fire Pump Controller](https://alliedpumps.com.au/wp-content/uploads/2020/06/Pyrokos-Fire-Pump-Controller-768x512.jpg.webp)